Manara - Qatar Research Repository
Browse
DOCUMENT
10.1016_j.eswa.2024.123167.pdf (7.33 MB)
DOCUMENT
supp_1-s2.0-S0957417424000320-mmc1.docx (43.25 kB)
1/0
2 files

Wearable wrist to finger photoplethysmogram translation through restoration using super operational neural networks based 1D-CycleGAN for enhancing cardiovascular monitoring

journal contribution
submitted on 2024-01-22, 06:52 and posted on 2024-01-22, 11:17 authored by Sakib Mahmud, Muhammad E.H. Chowdhury, Serkan Kiranyaz, Malisha Islam Tapotee, Purnata Saha, Anas M. Tahir, Amith Khandakar, Abdulrahman Alqahtani

Background and Motivations

Physiological signals, such as the Photoplethysmogram (PPG) collected through wearable devices, consistently encounter significant motion artifacts. Current signal processing techniques, and even state-of-the-art machine learning algorithms, frequently struggle to effectively restore the inherent bodily signals amidst the array of randomly generated distortions. This often leads to the modification or even the degradation of the underlying physiological information.

Methods

To enhance heart rate estimation from wrist PPG (wPPG) signals, this study introduces the Translation Through Restoration GAN (TTR-GAN). TTR-GAN comprises cascaded dual-stage 1D Cycle Generative Adversarial Networks (1D-CycleGANs) constructed using Super-ONNs. In the first phase, corrupted wPPG waveforms are blindly restored using a 1D-CycleGAN-based restoration framework. Subsequently, in the second phase, the restored wPPG waveforms are translated into clean finger PPG (fPPG) signals through a 1D-CycleGAN-based signal-to-signal translation or synthesis framework. Both the restorer and translator GANs undergo independent evaluation using robust temporal, spectral, and clinical metrics.

Results

The application of the multipass restoration scheme to the wPPG signals resulted in significantly lower entropy compared to the raw wPPGs, indicating reduced irregularity. Using the proposed PRTX metric to evaluate the translational ability of the multichannel translator CycleGAN, we achieved a substantial improvement of 35.88% in wrist-to-finger PPG translation. The correlation between the pulse rate and pulse rate variations estimated from the generated fPPG signals and the heart rate and heart rate variability readings from the ground truth ECG improved by approximately 10.4% and 14.7%, respectively, when compared to the raw wPPG signals.

Conclusion

The proposed TTR-GAN can be implemented in wearable devices to obtain reliable real-time cardiovascular data during daily activities.

Other Information

Published in: Expert Systems with Applications
License: http://creativecommons.org/licenses/by/4.0/
See article on publisher's website: https://dx.doi.org/10.1016/j.eswa.2024.123167

Funding

Open Access funding provided by the Qatar National Library.

History

Language

  • English

Publisher

Elsevier

Publication Year

  • 2024

License statement

This Item is licensed under the Creative Commons Attribution 4.0 International License.

Institution affiliated with

  • Qatar University
  • College of Engineering - QU