Simulation study of a coincidence detection system for non-invasive determination of arterial blood time-activity curve measurements

Download (1.3 MB)
journal contribution
submitted on 2024-07-10, 12:23 and posted on 2024-07-10, 13:11 authored by Yassine Toufique, Othmane Bouhali, Pauline Negre, Jim O’ Doherty

Background

Arterial sampling in PET studies for the purposes of kinetic modeling remains an invasive, time-intensive, and expensive procedure. Alternatives to derive the blood time-activity curve (BTAC) non-invasively are either reliant on large vessels in the field of view or are laborious to implement and analyze as well as being prone to many processing errors. An alternative method is proposed in this work by the simulation of a non-invasive coincidence detection unit.

Results

We utilized GATE simulations of a human forearm phantom with a blood flow model, as well as a model for dynamic radioactive bolus activity concentration based on clinical measurements. A fixed configuration of 14 and, also separately, 8 detectors were employed around the phantom, and simulations were performed to investigate signal detection parameters. Bismuth germanate (BGO) crystals proved to show the highest count rate capability and sensitivity to a simulated BTAC with a maximum coincidence rate of 575 cps. Repeatable location of the blood vessels in the forearm allowed a half-ring design with only 8 detectors. Using this configuration, maximum coincident rates of 250 cps and 42 cps were achieved with simulation of activity concentration determined from 15O and 18F arterial blood sampling. NECR simulated in a water phantom at 3 different vertical positions inside the 8-detector system (Y = − 1 cm, Y = − 2 cm, and Y = −3 cm) was 8360 cps, 13,041 cps, and 20,476 cps at an activity of 3.5 MBq. Addition of extra axial detection rings to the half-ring configuration provided increases in system sensitivity by a factor of approximately 10.

Conclusions

Initial simulations demonstrated that the configuration of a single half-ring 8 detector of monolithic BGO crystals could describe the simulated BTAC in a clinically relevant forearm phantom with good signal properties, and an increased number of axial detection rings can provide increased sensitivity of the system. The system would find use in the derivation of the BTAC for use in the application of kinetic models without physical arterial sampling or reliance on image-based techniques.

Other Information

Published in: EJNMMI Physics
License: https://creativecommons.org/licenses/by/4.0
See article on publisher's website: https://dx.doi.org/10.1186/s40658-020-00297-9

Funding

Qatar National Research Fund (NPRP9-328-1-066), The Experimental High Energy Physics Program in Qatar.

History

Language

  • English

Publisher

Springer Nature

Publication Year

  • 2020

License statement

This Item is licensed under the Creative Commons Attribution 4.0 International License.

Institution affiliated with

  • Hamad Bin Khalifa University
  • Qatar Computing Research Institute - HBKU
  • Texas A&M University at Qatar
  • Texas A&M at Qatar Advanced Scientific Computing Center - TAMUQ

Usage metrics

    Qatar Computing Research Institute - HBKU

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC