Manara - Qatar Research Repository
Browse
10.1186_s12903-023-03182-w.pdf (831.12 kB)

Radiopacity evaluation of calcium silicate cements

Download (831.12 kB)
journal contribution
submitted on 2024-01-04, 09:34 and posted on 2024-01-04, 10:39 authored by Havva Gozde Sen, Dilek Helvacioglu-Yigit, Ayca Yilmaz

Background

The aim of this study was to compare the radiopacity of calcium silicate cements using a digital imaging method.

Methods

Four calcium silicate cements, NeoMTA 2, OrthoMTA, ProRoot MTA, and Biodentine, were used in this study. Disk-shaped samples were prepared from each material and placed on a plexiglass plate. An aluminum step-wedge was placed alongside the samples on a digital sensor and exposed to 70 kVp and 8 mA from 30 cm away for 0.32 s. The greyness values ​​of the tested materials were measured digitally with the system software and compared with those of the step-wedge to determine the equivalent aluminum thickness.

Results

The radiopacity values, expressed in equivalent millimetres of aluminum, of the studied materials ProRoot MTA, OrthoMTA, NeoMTA 2, and Biodentine were 4.32 ± 0.17 mm Al, 3.92 ± 0.09 mm Al, 3.83 ± 0.07 mm Al, and 2.29 ± 0.21 mm Al, respectively. Statistically significant differences were found between the mean radiographic density values of the tested materials (p < 0.05).

Conclusion

ProRoot MTA was the most radiopaque root canal filling material among the tested materials. All materials, except Biodentine, were found to be compliant with the minimum radiopacity requirements of ISO 6876 and ADA 57 standards.


Other Information

Published in: BMC Oral Health
License: https://creativecommons.org/licenses/by/4.0
See article on publisher's website: https://dx.doi.org/10.1186/s12903-023-03182-w

Funding

Open Access funding provided by the Qatar National Library.

History

Language

  • English

Publisher

Springer Nature

Publication Year

  • 2023

License statement

This Item is licensed under the Creative Commons Attribution 4.0 International License.

Institution affiliated with

  • Qatar University
  • College of Dental Medicine - QU HEALTH

Methodology

Four calcium silicate cements, NeoMTA 2, OrthoMTA, ProRoot MTA, and Biodentine, were used in this study. Disk-shaped samples were prepared from each material and placed on a plexiglass plate. An aluminum step-wedge was placed alongside the samples on a digital sensor and exposed to 70 kVp and 8 mA from 30 cm away for 0.32 s. The greyness values ​​of the tested materials were measured digitally with the system software and compared with those of the step-wedge to determine the equivalent aluminum thickness.

Usage metrics

    Qatar University

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC