Energy and Exergy Analyses of Supercritical Coal‐Fired Power Plant With Single Reheat and Regenerative
This paper investigates energy and exergy analyses of 660 MW capacity supercritical coal power plant with single reheat and regenerative. The fuel utilized in the plant is a combination of sub‐bituminous and lignite coal. It is found that the turbine section of the system exhibits the highest energy efficiency (around 94.17%) and exergy efficiency (around 90.73%). Also, 82.07% of the total exergy destruction is found for the boiler, and the remaining 17.93% of the irreversibility is determined for the turbine, condenser, and other components. The overall cycle energy efficiency at maximum load is computed as 40.77%, while the overall cycle exergy efficiency at maximum load is found to be 39.69%. These findings provide valuable insights into the performance of the power plant and suggest the improvements needed in performance enhancement of the boiler.
Other Information
Published in: International Journal of Energy Research
License: http://creativecommons.org/licenses/by/4.0/
See article on publisher's website: https://dx.doi.org/10.1155/2024/8850236
Funding
Open Access funding provided by the Qatar National Library.
History
Language
- English
Publisher
WileyPublication Year
- 2024
License statement
This Item is licensed under the Creative Commons Attribution 4.0 International License.Institution affiliated with
- Qatar University
- College of Engineering - QU