Objectives

To describe first experience of integrating assessment of image quality in paediatric X-ray computed tomography (CT) with analysis of the radiation dose indices to develop reference doses called acceptable quality dose (AQD).

Methods

Image quality was scored by the radiologists at a tertiary care hospital in Qatar on a scale of 0 to 4 using the recently published scoring criteria. The patients undergoing head, chest and abdomen CT were divided in different weight groups as follows: < 5 kg, 5–< 15 kg, 15–< 30 kg, 30–< 50 kg, 50–< 80 kg and > 80 kg. The images that were clinically acceptable (score of 3) were included for assessment of median values of CTDIvol and DLP to obtain AQDs in different weight groups.

Results

After initial training in image quality scoring of CT images of 49 patients by three radiologists, the study on 715 patients indicated 665 studies (93%) were clinically acceptable as per scoring criteria. The median CTDIvol values for the above weight groups were 16, 20, 22, 22, 27 and 27 mGy and the median DLP values for these weight groups were 271, 377, 463, 486, 568 and 570 mGy cm, respectively, for head CT. Similar values are presented for chest and abdomen CTs.

Conclusions

The first ever experience of starting with image quality assessment and integrating it with analysis of dose indices to obtain AQD values shall provide a workable model for others and values for comparison within the facility and in other facilities leading to optimisation.

Key Points

• The first study to integrate image quality assessment with analysis of patient dose indices shows feasibility for routine practice in other centres.

• The values of acceptable quality dose (AQD) were provided for head, chest and abdomen CT of children divided into weight groups rather than age. They shall act as reference values for future studies.

• Verification of our findings on proportional increase in exposure parameters (CTDIvol and DLP) with weight by other investigators shall be helpful.

Other Information

Published in: European Radiology
License: https://creativecommons.org/licenses/by/4.0
See article on publisher's website: http://dx.doi.org/10.1007/s00330-020-07375-7

History

Language

  • English

Publisher

Springer Science and Business Media LLC

Publication Year

  • 2020

Institution affiliated with

  • Hamad Medical Corporation

Methodology

Image quality was scored by the radiologists at a tertiary care hospital in Qatar on a scale of 0 to 4 using the recently published scoring criteria. The patients undergoing head, chest and abdomen CT were divided in different weight groups as follows: < 5 kg, 5–< 15 kg, 15–< 30 kg, 30–< 50 kg, 50–< 80 kg and > 80 kg. The images that were clinically acceptable (score of 3) were included for assessment of median values of CTDIvol and DLP to obtain AQDs in different weight groups.

Usage metrics

    Manara - Qatar Research Repository

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC